北京福缘商住楼(20层)给排水设计毕业论文

 2021-04-12 10:04

摘 要

北京福缘商住楼建筑性质为高层商住楼,地下1层是车库,1层是商铺,2层是休息室,3-4层裙楼为办公楼,地上3-20层为单元住宅,总建筑面积约23000㎡。建筑物周围有完善的城市给水管网和排水管网,给水管网提供的压力为280kPa。

由于该商住楼的高度小于100m。故选择垂直竖向分区供水。市政供水管网的水压为280kPa,故1 至5层由城市供水管网直供。6至20层选择变速调速泵供水方式。本设计将加压部分划分为2个区,6到12层为加压低区,13到20层为加压高区。这样整个给水系统供水压力分散合理,不必设减压阀进行压力调节,增加供水安全性。

为方便商业与生活用水独立计费,裙楼1到4层商业用水单独供给。

排水采用厨房,卫生间单独排水,通气管均采用专用通气立管通气。泵房排水槽经汇集排至地下一层集水坑,经潜污泵提升排入市政污水管道。

根据规范,该建筑为一类公共建筑,属中度危险一级。室内消防流量40L/S。充实水柱取12m,水龙带长度取25m。

该建筑采用湿式自动喷淋灭火系统,报警阀间设于负一层,各层均设水流指示器和信号阀,其信号均送入消防控制中心进行处理。各层均采用自动喷淋系统,地下一层采用直立式喷头。各层均设试水装置以及放空管。屋顶消防水箱为36m3,贮存有10min自动喷水灭火系统、室内消火栓系统用水量。自动喷水灭火系统和消火栓系统的初期灭火由水箱供水,后期供水由地下室的消防水泵和自喷泵供水,各支管与立管连接处设置减压孔板。水池容积位置。自喷湿式报警阀的位置数量。

关键词:高层商住楼; 给水系统; 排水系统; 消火栓系统; 自动喷水灭火系统

Abstract

Beijing Fuyuan commercial and residential building properties for high-rise building, underground garage, layer 1 shops, layer 2 is the rest room, 3-4 layers of podium for the office, to 3-20 layer for residential units, with a total construction area of about 23000 square meters. There is a sound urban water supply network and drainage pipe network, the pressure of the supply pipe network is 280kPa.

Because of the height of the commercial building is less than 100m. Therefore, the vertical vertical partition water supply is chosen. The water pressure of the municipal water supply network is 280kPa, so the 1 to 5 layers are supplied by city water supply network.. 6 to 20 layers of variable speed control pump water supply mode. The design of pressurized part is divided into 2 districts, 6 to 12 for the low pressure area, 13 to 20 layers of high pressure. This water supply system water pressure is reasonable, do not have to adjust the pressure valve to increase water supply security.

For the convenience of commercial and living water independent billing, 1 building to the 4 floor commercial water supply alone.

The drainage uses the kitchen, the bathroom separate the drainage, the aeration tube all uses the special-purpose ventilation tube ventilation. The pump drain tank by pooling discharged to the basement sump, the submersible sewage pump upgrade into the municipal sewage pipe.

According to the specification, the building is a class of public buildings, is a moderate dangerous level. Indoor fire flow 40L/S. Enrich the water column 12M, 25m hose length.

The building uses wet sprinkler system, the alarm valve is located in the negative one, each layer are set up flow indicator and signal valve, the signal are sent to the fire control center for processing. Each layer uses the automatic sprinkler system, and the underground one uses the vertical head.. All the layers of a testing device and a vent pipe. The roof fire water tank is 36m3, storage water automatic sprinkler fire extinguishing system, indoor fire hydrant system 10min. Automatic sprinkler system and fire hydrant system of early fire extinguishing by water supply, post water from the basement of the fire pump and sprinkler pump water supply, each branch pipe and pipe arranged at the connecting position of decompression orifice plate. Pool volume position. Flowing wet alarm valve position number.

Key words: high-rise building; water supply system; drainage system; fire hydrant system; automatic sprinkler system.

目录

第一章 给排水工程设计任务书 1

1.1工程概况 1

1.2 设计依据 1

1.3 设计内容 1

1.4 设计图纸及要求 1

1.4.1 设计计算说明书 1

1.4.2 图纸: 1

第二章 设计说明书 2

2.1建筑给水系统设计 2

2.1.1给水系统选择 2

2.1.2 给水系统组成 3

2.1.3 给水管道布置与安装 3

2.2建筑排水系统设计 3

2.2.1排水方式选择 3

2.2.2通气管选择: 3

2.2.3 排水系统的组成 4

2.2.4排水管道及设备安装要求 4

2.2.5 关于清扫口、检查口 4

2.3建筑消火栓系统设计 5

2.3.1设计说明 5

2.3.2设计参数 5

2.3.3系统设计 5

2.4建筑自动喷水灭火系统 6

2.4.1设计说明 6

2.4.2基本设计数据 6

第三章 给水系统计算 8

3.1给水系统 8

3.1.1室内给水系统的计算 8

3.1.2地下室贮水池容积 10

3.1.3水力计算 10

3.2 变频给水设备的选择 17

第四章 消火栓给水系统计算 18

4.1消火栓系统 18

4.1.1计算管路的选择 18

4.1.2消火栓、水带、水枪型号的选择 18

4.1.3消防管网水力计算 18

4.1.4消防水池贮水量计算 19

4.1.5最不利点消火栓所需要的压力和实际射流量 19

4.1.6消防管网的水力计算 21

4.2水泵接合器设置 22

第五章 自动喷水灭火系统计算 24

5.1自动喷水灭火系统 24

5.1.1自动喷淋灭火系统的基本数据 24

5.1.2 喷头的选用与布置 24

5.1.3水力计算(作用面积法) 24

5.2 喷淋系统水泵选择 26

第六章 排水系统的计算 27

6.1排水系统 27

6.1.1 排水管网计算 27

6.2集水坑容积的计算 32

结论 33

致谢 34

参考文献 35

第一章 给排水工程设计任务书

1.1工程概况

北京福缘商住楼建筑性质为高层住宅,地下1层是车库,1层是商铺,2层是休息室,3-4层裙楼为办公楼,地上3-20层为单元住宅,总建筑面积约23000㎡。建筑物周围有完善的城市给水管网和排水管网,给水管网提供的压力为280kPa。

1.2 设计依据

(1)建筑给排水设计规范GB50015(2009年版)

(2)自动喷水灭火系统设计规范GB50084-2001 (2005年版)